(1) Virtual input ports

Port No.

Function

7000

Always OFF

7001

Always ON

7002

Voltage low warning for system-memory backup battery

7003

Abnormal voltage of system-memory backup battery

7004

(For future extension = Use strictly prohibited)

7005

(For future extension = Use strictly prohibited)

7006

Top-level system error = Message level error is present

7007

Top-level system error = Operation-cancellation level error is present

7008

Top-level system error = Cold-start level error is present

7009

(For future extension = Use strictly prohibited)

7010

Drive-source cutoff factor is present (including when waiting for cutoff reset input)

7011

Latch signal indicating that all-operation-cancellation factor is present (latch signal for
recognizing 1-shot cancellation factor; latch is cancelled by 7300-ON)

7012

All-operation-pause factor is present (including when waiting for restart switch signal) (Valid
only during automatic operation recognition)

7013

All-servo-axis-interlock factor is present (all-operation-pause factor + interlock input-port
factor)

7014

(For future extension = Use strictly prohibited)

7015

Voltage low warning for axis-1 absolute-data backup battery

7016

Abnormal voltage of axis-1 absolute-data backup battery (latched until power-on reset or
software reset

(restart)

)

7017

Voltage low warning for axis-2 absolute-data backup battery

7018

Abnormal voltage of axis-2 absolute-data backup battery (latched until power-on reset or
software reset

(restart)

)

7019

Voltage low warning for axis-3 absolute-data backup battery

7020

Abnormal voltage of axis-3 absolute-data backup battery (latched until power-on reset or
software reset

(restart)

)

7021

Voltage low warning for axis-4 absolute-data backup battery

7022

Abnormal voltage of axis-4 absolute-data backup battery (latched until power-on reset or
software reset

(restart)

)

7023 ~ 7030 (For future extension = Use strictly prohibited)

7031

Reading SIO CH1 (standard SIO) (reception ready) (*OFF if used for PC/TP connection)

7032

Reading SIO CH2 (expanded SIO)(reception ready)

7033

Reading SIO CH3 (expanded SIO)(reception ready)

7034

Reading SIO CH4 (expanded SIO)(reception ready)

7035

Reading SIO CH5 (expanded SIO)(reception ready)

7036

Reading SIO CH6 (expanded SIO)(reception ready)

7037

Reading SIO CH7 (expanded SIO)(reception ready)

7038 ~ 7070 (For future extension = Use strictly prohibited)

7071

Auto mode (Main application version 0.34 or later)

7072

Automatic operation (Main application version 0.34 or later)

7073 ~ 7100 (For future extension = Use strictly prohibited)