1. I/O Parameters

No.

Parameter name

Default value

(Reference)

Input

range

Unit

Remarks

1

I/O port assignment type

1

0 ~ 20

0: Fixed assignment
1: Automatic assignment (Priority: Slot 1

(standard I/O) ~ * Ports are assigned only
for the installed adjoining slots, starting from
slot 1 = For safety reasons)

2

Input port start number with fixed
standard I/O assignments (I/O1)

000

-1 ~ 599

0 + (Multiple of 8) (Invalid if a negative value is
set)

3

Output port start number with fixed
standard I/O assignments (I/O1)

300

-1 ~ 599

300 + (Multiple of 8) (Invalid if a negative value
is set)

4

Input port start number with fixed
expanded I/O1 assignments (I/O2)

-1

-1 ~ 599

0 + (Multiple of 8) (Invalid if a negative value is
set) (Slot next to the standard I/O slot)

5

Output port start number with fixed
expanded I/O1 assignments (I/O2)

-1

-1 ~ 599

300 + (Multiple of 8) (Invalid if a negative value
is set)

6

Input port start number with fixed
expanded I/O2 assignments (I/O3)

-1

-1 ~ 599

0 + (Multiple of 8) (Invalid if a negative value is
set)

7

Output port start number with fixed
expanded I/O2 assignments (I/O3)

-1

-1 ~ 599

300 + (Multiple of 8) (Invalid if a negative value
is set)

8

Input port start number with fixed
expanded I/O3 assignments (I/O4)

-1

-1 ~ 599

0 + (Multiple of 8) (Invalid if a negative value is
set)

9

Output port start number with fixed
expanded I/O3 assignments (I/O4)

-1

-1 ~ 599

300 + (Multiple of 8) (Invalid if a negative value
is set)

10 Standard I/O error monitor (I/O1)

1

0 ~ 5

0: Do not monitor, 1: Monitor * Some

exceptions apply.

11 Expanded I/O1 error monitor (I/O2)

1

0 ~ 5

0: Do not monitor, 1: Monitor (Slot next to the

standard I/O slot) * Some exceptions apply.

12 Expanded I/O2 error monitor (I/O3)

1

0 ~ 5

0: Do not monitor, 1: Monitor * Some

exceptions apply.

13 Expanded I/O3 error monitor (I/O4)

1

0 ~ 5

0: Do not monitor, 1: Monitor * Some

exceptions apply.

14 Number of ports using network-I/F-

card remote input

0

0 ~ 256

Multiple of 8

15 Number of ports using network-I/F-

card remote output

0

0 ~ 256

Multiple of 8

16 (For future extension = Change

prohibited)

0

0 ~ 256

Multiple of 8

17 (For future extension = Change

prohibited)

0

0 ~ 256

Multiple of 8

18 ~

19

(For extension)

0

20 Input filtering periods

2

1 ~ 9

msec Input signal is recognized when the status is

held for twice the period set by this parameter.

21 Register input filtering periods

2

1 ~ 9

msec Input signal is recognized when the status is

held for twice the period set by this parameter.

22 Remote-I/O-card fieldbus ready

timeout value

2000

0 ~

99999

msec Timeout check is not performed if “0” is set.