Parameters common to all axes – IAI America XSEL-KX User Manual

Page 318

Advertising
background image




302

Appendix

2. Parameters Common to All Axes

No.

Parameter name

Default value

(Reference)

Input range

Unit

Remarks

1

For future extension
(Change prohibited)

1111B

Reference

only

2

Default override

100

1 ~ 100

Used if not specified in program. (Invalid for SIO
operation)

3~8 (For extension)

0

9

For future extension
(Change prohibited)

11111111B

0B ~

11111111B

Reference

only

10 (For extension)

0

11 CP Default

acceleration

10

1 ~ 200

0.01 G

Used if not specified in position data, program or
SIO message, etc.

12 CP Default

deceleration

10

1 ~ 200

0.01 G

Used if not specified in position data, program or
SIO message, etc.

13 CP Default speed

30

1 ~ 250

mm/s

Used if not specified in SIO message or position
data, etc.

14 Valid selection when

operation point data
deceleration is 0

0

0 ~ 5

0: “Deceleration = Acceleration” when the

deceleration in the operation point data is “0”

1: “Deceleration = 0” when the deceleration in the

operation point data is “0”

15 For future extension

(Change prohibited)

~

0H ~

FFFFFFFFH

16~

19

(For extension)

0

~

20 For future extension

(Change prohibited)

2000

0H ~

FFFFFFFFH

21 CP Maximum speed

200

1 ~ 9999

mm/s

22 CP Maximum

acceleration

200

1 ~ 999

0.01 G

23 CP Maximum

deceleration

50

1 ~ 999

0.01 G

24 CP Minimum

emergency
deceleration

0

1 ~ 999

0.01 G

25 For future extension

(Change prohibited)

0

0H ~

FFFFFFFFH

26 For future extension

(Change prohibited)

0

0H ~

FFFFFFFFH

27 For future extension

(Change prohibited)

0

0H ~

FFFFFFFFH

28

For future extension
(Change prohibited)

0

0H ~

FFFFFFFFH

29

All-axis setting bit
pattern 1

0

0H ~

FFFFFFFFH

F

Bits 0 to 3:

(For future extension)

Bits 4 to 7:

Overrun (servo) error level (0: Operation-
cancellation level, 1: Cold-start level, 2:
Operation-cancellation level at reset,
thereafter cold-start level)

(Main application version 0.25 or later)

Bits 8 to 11: “Actual-position soft limit over (servo)”

error level (0: Operation-cancellation
level, 1: Cold-start level, 2: Operation-
cancellation level at reset, thereafter
cold-start level)

(Main application version 0.25 or later)

Bits 20 to 23: “Absolute-data backup battery voltage-

low warning error level (0: Message
level, 1: Cold-start level)

(Main application version 0.43 or later)

30

Default division angle

150

0 ~ 1200

0.1 deg

31

Default division
distance

0

0 ~ 10000

mm