[1] FG terminal

This terminal is used to ground FG on the enclosure. With a general-
purpose type, the enclosure is connected to PE in the AC input part inside
the controller.
With a compact type, FG and PE are not connected inside the controller.
Be sure to ground the FG terminal.


FG Terminal Specifications

Item

Overview

M4 3-point SEMS screw, 5 mm

Cable size

2.0 ~ 5.5 mm

2

Grounding method

Class D grounding



[2] Fuse holder (general-

purpose type only)

This half-cut fuse holder is used to protect overcurrent in the AC input
part. It prevents inflow of abnormal current generated by ground fault, etc.,
and uses a slow-blow fuse specified by IAI.


Overview of Fuse Holder Specifications

Item

Description

Holder

F-22001-A1 by Sato Parts

Fuse type

TWO 250V20A by Fuji Terminal

Melting
characteristics

Slow-blow

* With a compact type, the fuse holder is mounted on the board. Type:

FGMT5 AC250V10A by Fuji Terminal

[3] AC input connector

200-VAC, single-phase input connector.


AC Power Connector Specifications

Item

Overview

Connector name

POWER

Connector

GMSTB2.5/3-STF-7.62 by Phoenix Contact
3-pin, 2-piece connector

Supported cable size 1.25 ~ 2.5 mm

2

(AWG12 ~ 16)

Connected to

AC power source

Terminal
assignments

1

In

N

AC power input, N side

2

In

L

AC power input, L side

3

PE (Protective grounding line)

*