If multiple controllers are to be connected on top of one another, prevent the controller above from
taking in the exhaust air from the controller below.


3. Power Source

Provide a single-phase power source of 200 to 230 VAC.


4. Noise Measures and Grounding

(1) Wiring and power source

PE on the power terminal block is used for protective grounding. Provide Class D grounding from this
terminal.
Use a grounding cable with a wire size of 1.0 mm

2

(#AWG17) or more, which should not be smaller

than the AC power cable.
Install a noise filter in the AC line to prevent the noise generating in the controller from traveling
through the power line to enter other unit.











Install the noise filter near the power connector on the X-SEL controller side.
Use of a noise filter by Densei-Lambda is recommended. The applicable noise filter model varies
depending on the robot specification, as shown below.

Recommended noise filter models (by Densei-Lambda)
Robot specification

Model

Arm length 700/800 specification, high-speed specification

MXB-1220-33

Other types

MXB-1210-33

Airflow direction

Fan

Airflow

150 mm min.

150 mm min.

150 mm

min.

200-VAC power source

Class D grounding
(protective grounding)

Noise

filter