 Error List (MAIN application) (In the panel window, the three digits after “E” indicate an error number.)

Error No.

Error name

Description, action, etc.

207

Update file name error (IAI protocol)

The update program file name selected in the update mode is invalid. Select the
correct file and repeat the update procedure from the beginning.

20E

Motorola S byte count error

The update program file is invalid. Check the file.

20F

Update target specification error (Received by the application)

An update target specification command was received by the application system.
To update the target, restart the controller and repeat the update procedure from
the beginning.

630

Update system code error (Detected by the application)

The update system code is invalid.

631

Update unit code error (Detected by the application)

The update unit code is invalid.

632

Update device number error (Detected by the application)

The update device number is invalid.

801

SCIF overrun status (IAI protocol reception)

Communication failure. Check for noise, connected equipment and
communication setting.

802

SCIF receive ER status (IAI protocol reception)

Communication failure. Check for noise, shorted/disconnected communication
cable, connected equipment and communication setting. This error will also occur
when establishing communication with the PC/TP wrongly connected to SIO-CH1
being opened to the user.

803

Receive timeout status (IAI protocol reception)

The transfer interval after the first received byte is too long. Possible causes
include disconnected communication cable and error in the connected
equipment.

804

SCIF overrun status (SEL reception)

Communication failure. Check for noise, connected equipment and
communication setting.

805

SCIF receive ER status (SEL reception)

Communication failure. Check for noise, shorted/disconnected communication
cable, connected equipment and communication setting.

806

SCIF receive ER status due to other factor (SEL reception)

Communication failure. Take the same action specified for error No. 804 or 805.

807

Drive-source cutoff relay ER status

The motor-drive power ON status remains ON even after the drive-source cutoff
processing was actuated. The drive-source cutoff relay contact may have melted.

808

Power OFF status during slave parameter write

The power was turned off while writing slave parameters. (This error can be
detected only when a backup battery is used.)

809

Power OFF status during data write to flash ROM

The power was turned off while writing data to the flash ROM. (This error can be
detected only when a backup battery is used.)

80A

Expanded-SIO overrun status (SEL reception)

Communication failure. Check for noise, connected equipment and
communication setting.

80B

Expanded-SIO parity ER status (SEL reception)

Communication failure. Check for noise, shorted/disconnected communication
cable, connected equipment and communication setting.

80C

Expanded SIO framing ER status (SEL reception)

Communication failure. Check for noise, shorted/disconnected communication
cable, connected equipment and communication setting.

80D

Expanded-SIO receive ER status due to other factor (SEL
reception)

Communication failure. Take the same action specified for error No. 80A, 80B or
80C.

80E

Expanded-SIO receive buffer overflow status (SEL reception)

The receive buffer overflowed. Excessive data was received from outside.

80F

Ethernet control status 1

Ethernet control information (for analysis)

810

Ethernet control status 2

Ethernet control information (for analysis)

811

Maintenance information 1

Maintenance information (for analysis)

812

Maintenance information 2

Maintenance information (for analysis)