A

pp
end

ix


 Error List (MAIN core) (In the panel window, the three digits after “E” indicate an error number.)

Error No.

Error name

Description, action, etc.

A70

SCIF overrun error

Communication error. Check for noise, connected equipment and communication
setting. (When updating the application, connect to a PC and use IAI’s update
tool.)

A71

SCIF framing error

Communication error. Check for noise, shorted/disconnected communication
cable, connected equipment and communication setting. (When updating the
application, connect to a PC and use IAI’s update tool.)

A72

SCIF parity error

Communication error. Check for noise, shorted/disconnected communication
cable, connected equipment and communication setting. (When updating the
application, connect to a PC and use IAI’s update tool.)

A73

IAI protocol header error

Communication protocol error. Check for noise and connected equipment. (When
updating the application, connect to a PC and use IAI’s update tool.)

A74

IAI protocol terminal ID error

Communication protocol error. Check for noise and connected equipment. (When
updating the application, connect to a PC and use IAI’s update tool.)

A75

IAI protocol command ID error

Communication protocol error. Check for noise and connected equipment. (When
updating the application, connect to a PC and use IAI’s update tool.)

A76

IAI protocol checksum error

Communication protocol error. Check for noise and connected equipment. (When
updating the application, connect to a PC and use IAI’s update tool.)

A77

Motorola S record type error

The update program file is invalid. Check the file.

A78

Motorola S checksum error

The update program file is invalid. Check the file.

A79

Motorola S load address error

The update program file is invalid. Check the file.

A7A

Motorola S write address over error

The update program file is invalid. Check the file.

A7B

Flash timing limit over error (Write)

Error writing the flash ROM (When updating)

A7C

Flash timing limit over error (Erase)

Error erasing the flash ROM (When updating)

A7D

Flash verify error

Error erasing/writing the flash ROM (When updating)

A7E

Flash ACK timeout

Error erasing/writing the flash ROM (When updating)

A7F

Head sector number specification error

Error erasing the flash ROM (When updating)

A80

Sector count specification error

Error erasing the flash ROM (When updating)

A81

Write-destination offset address error (Odd-numbered address)

The address written during flash ROM write (when updating) is invalid. Check the
update program file.

A82

Write-source data buffer address error (Odd-numbered address) Error writing the flash ROM (When updating)

A83

Invalid code sector block ID error

The flash ROM is new, or the program currently written to the flash ROM is invalid
because the last update was aborted. The ROM can be updated without problem.

A84

Code sector block ID erase count over

The number of times the flash ROM was erased exceeded the allowable count.