㽽 Status display LED

Conditions when each LED is lit are as follows:

Condition when LED is lit

JOG

Jog operation is available with the 1- to ALL- or 1+ to ALL+ keys.

SERVO

The servo ON/OFF commands are available with the 1- to ALL- or 1+ to ALL+ keys.

MOVE

Position movement and continuous movement are available with the 1- to ALL- or 1+
to ALL+ keys.

HOME

Home position return operation is available with the 1- to ALL- or 1+ to ALL+ keys.

SVOFF

It is lit when the servo is OFF for all the effective physical axes.

S-VEL

It is lit when Effective is selected for the safety velocity.

ERROR

It is lit when an error occurs in the controller.

EMG

It is lit when the controller is in an emergency stop condition.

POWER

It is lit when the power to the Teaching Box is ON.

READY

It is lit when the controller is in a ready condition.

㽾 WRT key (write key)

It transfers edit data to the controller. (Stores data in the memory of the controller.)

It transfers only data that is displayed in the LCD display. (Cannot transfer data by merging

more than one position No., program step No., etc.)

㽿 STOP key

It gives an operation stop command to all the effective physical axes. This is valid in the

axis-operable mode.

㾀 MOVE key

It changes the operation mode of the axis operation keys (1- to ALL-, 1+ to ALL+) to the

POSITION MOVEMENT mode. The MOVE LED lights up. This key is valid in the

axis-operable modes.

㾁 SERVO key

It changes the operation mode of the axis operation keys (1- to ALL-, 1+ to ALL+) to the servo

ON/OFF mode. The SERVO LED lights up. This is valid in the axis-operable modes.

㾂 HOME key

It changes the operation mode of the axis operation keys (1- to ALL-, 1+ to ALL+) to the

HOME POSITION RETURN mode. The HOME LED lights up. This is valid in the

axis-operable modes.