Press the ESC key to return to the Teac screen.

To move the Z-axis manually, it is required to release
the brake. Therefore, the Z-axis may lower by the
weight of the hand attached to the end when the
brake is released. Do not carry out teaching for
manual movement to the Z-axis.

Move each axis to any given position manually.
Pressing the F2 (Scan) key incorporates the current
position of the axis No. over which the cursor is
located onto the input screen.

Press the return key to move the cursor to the next
axis, and press the F2 (Scan) key.

Press the WRT key to transfer the position data to
the controller.
The position No. advances to 12.

* When the screen is changed with the PAGE UP

and PAGE DOWN keys or ESC key before data
transfer, the input data becomes invalid.

70