(5) I/O monitoring and position check
Input and output ports can be monitored during teaching operation. In addition, it is also
possible to move the actuator to the location of the position data with teaching and check its
position.
㽲 I/O monitoring
Select In or Out among the function keys in a Teac screen condition.
In: Input ports
Out: Output ports
The port No. display can be changed with the PAGE UP and PAGE DOWN keys.
Input ports
Output ports
Pressing the F1 (0/1) key can turn OFF/ON (0/1) the
output port at the cursor location.
Every time the F1 key is pressed, the port is
changed between OFF and ON (0 and 1).
The cursor is moved with the
Ż ź Ÿ Ź keys.