(6) User-specified output port operation

The output ports set for the parameter can be easily turned ON/OFF.

Select UsrO among the function keys in a Teac screen condition.

(A) User-specified output port status

The conditions of user-specified output ports are displayed as 1 (=ON) and 0 (=OFF).

(The conditions are displayed from the first specified port for the number of the specified

ports.)

(B) Current position and servo ON/OFF

The current position and servo ON/OFF condition (N=ON, F=OFF) are displayed for each

axis.

(C) Function for operation of user-specified output ports

This is the function for ON/OFF operation of user-specified output ports.

This function is allocated to Usr1, Usr2, Usr3….in this order from the first user-specified

port for the number of specified ports.

(Usr1 to Usr4 and Usr5 to Usr8 are changed with the SF key.)

ON/OFF operation can be performed for each output port by pressing the function keys

(F1 to F4) corresponding to Usr1 to Usr4 and Usr5 to Usr8.

(When the port status display is 0 [OFF], the port ON command is given. When the port

status display is 1 [ON], the port OFF command is given.)