102

5.2.5 Initial

Set


Select either 2-point or 3-point stop.

Touch Initial set in the MEC MENU window.







Unless the password is set to “0000”, the password input window opens before moving to
Operation Pattern Setting window.


Enter the password number with the numeric keys then
touch .




The menu will move to the 2-point/3-point Stop Setting window at the beginning when a
correct password setting is confirmed.


Choose and touch either 2 position or 3 position.







Pressing Select window opens.

Touch Not used when the positioning operation is
required.
Choose and touch Use when the pressing operation is
required.
(Note) Be careful since the completion signal would not

rise if Not used is selected in this window.

*

The output signal will be LS0, LS1 and (LS2)
if Not used is selected. It will be PE0, PE1 and
(PE2) when Use is selected.


For 3-point stop, The menu moves to the select menu of the command method for
intermediate point.

Select either Both OFF or Both ON for the input signal to
ST0 and ST1 for the positioning at the intermediate point
for 3-point stop.

The password is set to ‘5119’ (at delivery).
The password can be changed in ‘System Password
Change’ under Environment Setting.