IAI America SEP-PT User Manual

Page 72

Advertising
background image

66

[Pause Signal *STP]

When the Single Solenoid Type is set for the Operation Mode and the Operation Pattern 4 is
set, select whether or not the STOP signal STP (Input in IN2) is used.


Selecting Back returns to the preceding window.







[Servo Control SON]

Select whether or not the servo-motor control signal (Input signal SON (Servo-Motor ON/OFF
Control) to IN3) is used.


Selecting Back returns to the preceding window.







[Output Signal Selection

Operation Pattern 0, 1, 2, 5]

When the Operation Pattern is set to “0”, “1”, “2” or “5”, set the OUT2 and OUT3 output signals
after the Control is selected.
Select one of the three patterns in the table.

Selection No. 1

Selection No. 2

Selection No. 3

OUT2

HEND
(Homing Completion Signal)

SV
(Servo ON output signal)

HEND
(Homing Completion Signal)

OUT3

*ALM
(Alarm output Signal)

*ALM
(Alarm output Signal)

SV
(Servo ON output signal)



Selecting Back returns to the preceding window.







Advertising