IAI America SEP-PT User Manual
Page 126
 
120
[4] Position Setting Operation Example
The operation procedure is described taking a specific example. 
 
1)
Position, Velocity or Acceleration/Deceleration Setting 
Explained below is the case for 2-point stop as an example. 
The position setting is performed for the reciprocating movement between 10.0 mm and 
100.0 mm.
Forward Position (Backward Point) :100.0mm, Backward Position (Forward Point) :10.0mm, 
Reciprocating Movement Speed: 50mm/sec, Reciprocating Movement Acceleration: 0.3G, 
Reciprocating Movement Deceleration: 0.3G 
No. Operation
Window
Remarks
1
Touch Pos. Edit in the MEC 
MENU window.
 
 
2
In the case of the password 
value except for “0000”, the 
password input window is 
displayed. 
Input the password. 
The password for positioning 
command can be set in 
‘parameter No. 20 Password 
for Position Data Edit’ under 
Parameter Edit. 
3
Set the backward position 
(stop position on the forward 
point), the positions related 
to it and acceleration/ 
deceleration speed. 
 
Touch the BackwardPos.
When
MENU is touched, the
MEC MENU window is 
returned. 
4
Touch the value for the 
position. 
Touching Tb1 return to the 
Forward Position/Backward 
Position setting window in 
the Position Setting window. 
 
5
Touch 1, 0, then
.
When the value input is 
stopped, touch ESC. The 
value will not be set and the 
previous position setting 
window will be returned. 
6
“10.00” is displayed in the 
position data section.
Touching Tb1 return to the 
Forward Position/Backward 
Position setting window in 
the Position Setting window.