IAI America SEP-PT User Manual
Page 110
 
104
Operation Pattern
 
The PMEC, AMEC or ERC3 (MEC mode) controller has the 2 operation patterns. 
Each of these 6 patterns is described as in the table. Also, the corresponding air cylinder circuit is 
described for reference. [Refer to Initial Setting and Stop Position Setting for the setting.] 
Operation
Pattern
Contents
Air Cylinder Circuit
(Reference)
Electric Cylinder
Connection Procedure
2-Point S
top
(2-P
oint Posit
ioning
)
[Single Solenoid
T
y
pe]
1-Input, 2-Point Movement
The actuator 2-Point movement 
is available using the same 
control function as for the air 
cylinder. 
Backward and forward points 
can be determined. 
Speed and acceleration settings 
in the actuator movement are 
available. 
The pressing operation is 
available. 
Set ST0 ON to move to the 
backward point and OFF to 
return to the forward point. 
PLC
A
B
R1
R2
Air Cylinder
Solenoid
Spring
P (Air)
Forward Position
Detection (LS0)
Backward Position
Detection (LS1)
Sensor
Movement Signal 1
(ST0)
PLC
ERC3,
AMEC
/PMEC
Movement Signal 1
(ST0)
Forward Position
Detection (LS0)
Backward Position
Detection (LS1)
Electric Cylinder
Dedicated 
Cable
Power 
Supply
PLC
A B
R1
R2
Air Cylinder
Solenoid A
P (Air)
Forward Position
Detection (LS0)
Backward Position
Detection (LS1)
Sensor
Solenoid B
Movement to Backward
Position 2 (ST1)
Movement to Forward
Position 1 (ST0)
[Doubl
e Sole
noid
T
y
pe]
2-Input, 2-Point Movement
PLC
B A
R
R
Solenoid A
Solenoid B
Air Cylinder
P (Air)
Sensor
Forward Position
Detection (LS0)
Backward Position
Detection (LS1)
Movement to Backward
Position 1 (ST1)
Movement to Forward
Position 2 (ST0)
PLC
ERC3,
AMEC
/PMEC
Forward Position
Detection (LS0)
Backward Position
Detection (LS1)
Electric Cylinder
Dedicated 
Cable
Power 
Supply
Movement to Backward
Position 1 (ST1)
Movement to Forward
Position 2 (ST0)
3-Point S
top
(3-P
oint Posit
ioning
)
[3-Point Posit
ioning]
2-Input, 3-Point
Mt
The actuator 2-Point movement 
is available using the same 
control function as for the air 
cylinder. 
Backward and forward points 
can be determined. 
Setting of intermediate point is 
available, and positioning to the 
intermediate point is also 
available. 
Speed and acceleration settings 
in the actuator movement are 
available. 
The pressing operation is 
available. 
Set ST1 ON to move to the 
backward point and ST0 ON to 
forward point. 
 
[Both switches ON to move to 
intermediate point] 
Set both ST0 and ST1 ON to 
stop at intermediate point for 
positioning. 
Set both ST0 and ST1 OFF and 
it stops on the way. 
 
[Both switches OFF to move to 
intermediate point] 
Set both ST0 and ST1 OFF to 
stop at intermediate point for 
positioning. 
Set both ST0 and ST1 ON and it 
stops on the way. 
PLC
Forward Position
Detection (LS0)
Backward Position
Detection (LS1)
Intermediate Position
Detection (LS2)
Air Cylinder
P (Air)
Sensor
P (Air)
P (Air)
Movement Signal 1
(ST0)
Movement Signal 2
(ST1)
PLC
ERC3,
AMEC
/PMEC
Movement Signal 1
(ST0)
Movement Signal 2
(ST1)
Forward Position
Detection (LS0)
Backward Position
Detection (LS1)
Intermediate Position 
Detection (LS2)
Electric Cylinder
Dedicated 
Cable
Power 
Supply
(Note): The symbols in the air cylinder circuit diagram above are those applied for PMEC, AMEC or
ERC3 (MEC mode). 
Refer to “PMEC/AMEC Instruction Manual” and “ERC3 Instruction Manual” for the details of 
the signal symbols.