7) Energy-Saving Function… If the energy saving function is turned active, the servo will turn

off automatically to save electricity in a certain while after a
positioning is complete.
Set the time in the parameter in advance.

Parameter No.

Parameter Name

Initial Value

Setting range

10

Auto Servo OFF Delay Time [sec]

1

0 to 9999


[Automatic Servo off]

The servo automatically turns off after a specified time once the position is complete. When
the next position is commanded, the servo will automatically turn on and execute the position.
It will save power consumption since the no current is used during servo off.






















Velocity

Position where the actuator is pressed against
the work and it is decided that the pressing operation
has been completed.

Work Part

Pressing Width

Target Position

Pressing Operation Starting Point

T

T: Time Set to Parameter No. 10

In Automatic Servo-Motor OFF Mode
(Green LED is flashing)

Servo Condition

Movement Signal 1 (ST0)
Movement Signal 2 (ST1)

Actuator Movement

Start Point Detection (LS0)
End Point Detection (LS1)
Intermediate Point Detection (LS2)

Completion of Start Point Positioning (PE0)
Completion of
End Point Positioning (PE1)
Completion of Intermediate Point Positioning (PE2)