2 specifications, Communication specifications, When supporting rs-232-c commands – Yokogawa DR240 User Manual

Page 32: When reading in instantaneous value data, When displaying communication conditions, Protocols

Advertising
background image

4-3

IM DR231-11E

Overview and Specifications of Ethernet Interface

4

4.2 Specifications

Communication Specifications

Transmission specifications

: 10BASE-T (CSMA/CD, 10Mbps, Baseband)

Electrical/Mechanical specifications: Conforms to IEEE802.3 (Frames are not supported.)
Protocols

: TCP, IP, UDP, ARP, ICMP

When supporting RS-232-C commands

Communication format

: TCP/IP

Keepalive

: Turn ON/OFF using dip switch 3. When turned ON, it de-

tects timeouts and disconnects communication

Command data

: ASCII

Response data

: ASCII, BINARY

Receive buffer length

: 200 bytes

Maximum number of connections

: 1

Port No.

: 34150

When reading in instantaneous value data

Communication format

: TCP/IP

Keepalive

: Turn ON/OFF using dip switch 3. When turned ON, it de-

tects timeouts and disconnects communication

Command data

: ASCII

Response data

: ASCII, BINARY

Receive buffer length

: 200 bytes

Maximum number of connections

: 4

Port No.

: 34151

When displaying communication conditions

Communication format

: TCP/IP

Command data

: ASCII

Response data

: ASCII

Receive buffer length

: 200 bytes

Maximum number of connections

: 1

Port No.

: 34159

Protocols

Application layer

Transport layer

Network layer

Data link layer

Physical layer

DARWIN services

TCP UDP

IP ICMP ARP

Ethernet (10BASE-T)

IP: Internet Protocol
TCP: Transmission Control Protocol
UDP: User Datagram Protocol
ICM: FInternet Control Message Protocol
ARP: Address Resolution Protocol
Part of the software which belongs to the regents of University of California is introduced here.