6 control and execution command – Yokogawa DR240 User Manual
Page 71

6-17
IM DR231-11E
Commands
6
6.6 Control and Execution
Command
PS
Starts or stops recording.
Mode
Operation mode
Setting
PSp1<terminator>
p1
0 Recording starts.
1 Recording stops.
MP
Starts or stops manual printing.
Mode
Operation mode
Setting
MPp1<terminator>
p1
0 Manual printing starts.
1 Manual printing stops.
Example
Start manual printing.
MP0
LS
Starts or stops list printing.
Mode
Operation mode
Setting
LSp1<terminator>
p1
0 List printing starts.
1 List printing stops.
Example
Start list printing.
LS0
HD
Starts or stops header printing.
Mode
Operation mode
Setting
HDp1<terminator>
p1
0 Header printing starts.
1 Header printing stops.
Example
Start header printing.
HD0
SU
Starts or stops setup list printing.
Mode
Operation mode
Setting
SUp1<terminator>
p1
0 Setup list printing starts.
1 Setup list printing stops.
Example
Start setup list printing.
SU0
MS
Starts message printing.
Mode
Operation mode
Setting
MSp1<terminator>
p1
01 to 20 (message number)
Example
Start printing message No. 5.
MS05
AK
Confirms the current alarm status.
Mode
Operation mode
Setting
AKp1<terminator>
p1
0 Confirms the current alarm status.
Example Confirm the current alarm status.
AK0
AR
Resets an alarm.
Mode
Operation mode
Setting
ARp1<terminator>
p1
0 The alarm is reset.
Example
Reset the alarm.
AR0
IR
Resets the timer.
Mode
Operation mode
Setting
IRp1<terminator>
p1
0 The timer is reset.
Example
Reset the timer.
IR0
AC
Clears the alarm buffer.
Mode
Operation mode
Setting
ACp1<terminator>
p1
0 The alarm buffer is cleared.
Example
Clear the alarm buffer.
AC0
MC
Clears the message buffer.
Mode
Operation mode
Setting
MCp1<terminator>
p1
0 The message buffer is cleared.
Example
Clear the message buffer.
MC0
EX
Computation start/stop, restart of
computed data after they are cleared,
and release of statuses after
completing measurement.
Mode
Operation mode
Setting
EXp1<terminator>
p1
Computation start/stop, restart of computed
data after they are cleared, and execution of
releasing statuses after completing
measurement.
0: Computation start
1: Computation stop
2: Restart of computed data after they are
cleared
3: Computed data clear
4: Release of statuses after completing
measurement
Example
Start the computation.
EX0
Comments
• This command is effective only with the optional
computation functions or a floppy disk drive
function or with a pulse module installed.
• If MATH is set for level action in the event/action,
a computation start/stop/start after clearing the
computed data cannot be done using EX
command.
• This command is not executable during the
saving/reading of setup data.
MW
Stores the measured data/computed
data on a RAM disk.
Mode
Operation mode
Setting
MWp1, p2, p3, p4, p5<terminator>
p1
Retention mode
DIRECT
Data storage starts immediately
after sending an MW command.
TRIGER
Data storage starts after a trigger
signal is generated.
REPEAT Specified data are repeated for
storage each time the trigger
signal is generated.
p2
File name (up to eight characters for other
than REPEAT, up to five characters for
REPEAT)
p3
Retention interval
INTVL
Data are stored at measurement
intervals.
1 min/2 min/5 min/10 min
Data are stored at specified
intervals.
6.6 Control and Execution Command