IM DR231-11E

KEY_LOCK_ON
Key lock is turned on.
MATH_START
Starts computation.
MATH_CLR_START
Clears computation results then re-start
computation.
MATH_STOP
Stops computation.
MATH_ACK
Clears the computation status indication.
REPORT_START
Starts report.
REPORT_STOP
Stops report.
REP_RECALL_START
Starts printing the report.
REP_PRINT_STOP
Stops printng the report.
KEY_LOCK_OFF
Key lock is turned off.
S/U_LIST_START
Setup list printing starts.
S/U_LIST_STOP
Setup list printing is stopped.
MSG_PRINT
Message printing begins.
ALM_BUF_CLEAR
Alarm buffer is cleared.
MSG_BUF_CLEAR
Message buffer is cleared.
RAM_INIT
Internal memory is initialized.
COMM_INF
Information on communication module
parameter
MODULE_INF
Module information
RE_SYSTEM (DR232/DR242 only)
Reconstruction of a system
ALL_ITEM
All items of parameter p1

p2

Type of screen
OFF

No display on the function screen

FUNC1 Screen that appears when the

FUNC key is pressed.

FUNC3 Screen that appears when the

FUNC key is pressed for 3
seconds.

INIT

Initialize.(Effective only when p1
is set to ALL_ITEM.)

Example

Display setup list printing start on the FUNC1
screen.

XFS/U_LIST_START, FUNC1

Comments

• More than one function can be displayed on each

function screen.

• A function can be easily executed by being

displayed on the function screen.

XS

Sets which settings are to be
displayed on the setting screen.

Mode

Setup mode

Setting

XSp1, p2<terminator>

p1

Contents to be displayed on the set screen
SYSTEM: System settings
UNIT

Unit settings

MATH

Settings for computation of
respective computation
channels

CONST

Settings for computation
constants

MEMORY

Settings relating to data

saving/reading in the built-
in RAM disk

FLOPPY

Settings relating to data
saving/reading on floppy
disks

ZONE

Zone recording settings

PARTIAL

partially expanded record
settings

CHART2

Second chart speed settings

TAG

Tag settings

TIMER

Timer settings

LOGIC

Logic settings

MESSAGE

Message settings

GROUP

Group settings

TREND

Turning on or off analog
records for each channel

DIGITAL_PR

Turning on or off digital
records for each channel

LIST_PR

Turning on or off list
printing for each channel

MANUAL_PR Turning on or off manual

printing for each channel

SCALE_PR

Turning on or off scale
printing for each channel

ALARM_PR

Turning on or off alarm
printing for each channel

HEADER

Header settings

TITLE

Title settings

MOVE_AVE

Moving average settings

INTERPOL

Step interpolation settings

MATCH_TIME Match time settings
LIST_FMT

List printing format settings

COPY

Copy contents settings

DST

Summer/winter time

ALL_ITEM

All items of parameter p1

p2

Type of screen
OFF

Nothing appears on the set screen.

SET

Screen when the set key is pressed

SET3 Screen when the set key is pressed for

3 seconds

INIT Initialize. (Effective only when p1 is

set to ALL_ITEM.)

Example

Show the settings of a tag on the screen for which
you have pressed the SET key.

XSTAG, SET

Comments

• More than one setting item can be displayed on

the set screen.

• By displaying a setting item on the set screen, the

setting item can be easily set.

• MATH in parameter p1 is valid only for recorders

with the optional computing function or floppy
disk drive function.

• CONST is valid only for recorders with the

optional computing function.

• MEMORY and FLOPPY are valid only for

recorders with the floppy disk drive function.

XB

Sets the burnout.

Mode

Setup mode

Setting

XBp1, p2<terminator>

p1

Channel number (001 to 560)

p2

Selection of burnout
OFF
UP

Upscale traveling beyond the scale

DOWN Downscale traveling beyond the scale

Example

Set channels 01 to 10 of subunit 0 to upscale
burnout.

XB001-10, UP

Comments

• If channels are to be set successively, the setting is

effective only when the channels are in the same
unit.

6.5 Other Settings