4-5

IM DR231-11E

Overview and Specifications of Ethernet Interface

4

4.3 Names and Functions of Each Section

Warning

A warning is being indicated when STS2 is lit. You can check the details of the warning by display-
ing the communication condition (see section 4.8 “Displaying the Communication Information”).

Error

An error occurs when the communicaiton fails. When communication error or EEPROM error
occurs, the DR must be repaired.

STS1, STS2 Indication

Type of Error

Cause

Number of blinks by STS1 is 1 and by STS2 is 1

Configuration error

IP address is not set.

Number of blinks by STS1 is 1 and by STS2 is 2

Communication error Error occurred while processing

TCP/IP.

Number of blinks by STS1 is 2 and by STS2 is 1

EEPROM error

EEPROM malfunction