Internal fault report – Edwards Signaling eFSA250 User Manual
Page 203
Chapter 4: Reports
E-FSA64 and E-FSA250 Technical Reference Manual
191
To view a Response Quality diagnostic report:
1. Press the Menu button and choose Reports.
2. Choose Diagnostics.
3. Choose Response Quality.
4. Enter the quality percentage (0 to 100).
This is a communication percentage value that is
used to display the device’s minimum recorded
pulse strength percentage. Enter “80” to list
devices that are communicating up to 80 percent
of their maximum pulse strength. Enter “50” to list
devices that are communicating up to 50 percent
of their maximum pulse strength (devices
communicating better than 50% are not included
in the report).
Main Menu
Reports
Test
Control
Program
Reports
Internal Status
Device Details
Diagnostics
Diagnostics
Comm Retries
Response Quality
Response Quality
Quality % 000
Internal Fault report
The Internal Fault report displays information about an internal fault event (event
ID 48) that has occurred in the system. The report contains information that is
important for technical support when troubleshooting the internal fault event and
should typically only be run when you are asked to do so by a technical support
representative.
To view an Internal Fault report:
1. Press the menu button and choose Reports.
2. Choose Int. Fault.
Main Menu
Reports
Test
Control
Program
Reports
Device Details
Diagnostics
Int. Fault