Figure 4, Transmitter parts – inside – Vaisala GMW90 User Manual

Page 19

Advertising
background image

Chapter 2 ___________________________________________________________ Product Overview

VAISALA ________________________________________________________________________ 17

1310-039

Figure 4

Transmitter Parts – Inside

1 = Mounting base.

2 = Opening for cable (wiring from top).

3 = Terminal label.

4 = Opening for cable (wiring from behind, recommended).

5 = Label for RS-485 baud rate DIP switch settings.

Included only on digital models.

6 = Orientation arrow – should point up after the mounting base has

been installed.

7 = Screw terminals.

8 = Place for zip tie (for cable strain relief)

9 = Transmitter body.

10 = RS-485 termination jumper (connects a 120 Ω resistor).

Included only on digital models.

11 = GM10 module (measures CO

2

).

12 = DIP switches for common configuration options. Digital models

have an extra DIP switch bank for transmitter address.

13 = Grip for slide.

14 = TM10 module (measures temperature only) or

HTM10 module (measures humidity and temperature).

15 = HUMICAP

®

sensor (on models with humidity measurement).

2

3

4

6

8

7

14 15

1

9

13

10

11

5

12