Reverting to Factory Settings

GMW90 series transmitters, including factory-customized transmitters,

can be reverted to their original shipping configuration using the DIP

switches or the service port.

Reverting the transmitter to factory settings clears all user configuration

that has been done using the service port. User-made adjustments are also

cleared from the GM10 and HTM10 measurement modules. The factory

calibration will remain.

Reverting to Factory Settings Using DIP

Switches

1.

Disconnect the transmitter cover from the mounting base.

2.

Make a note of the DIP switch positions before changing anything,

so you can restore the positions later.

3.

Analog output models: Set the DIP switches as shown in Figure 30

below: move all switches up.

Digital output models: Set the DIP switches in the leftmost DIP

switch bank as shown in Figure 31 below. Do not move the

switches in the other bank.

1204-040

Figure 30

DIP Switch Factory Reset (GMW93/94)

1209-028

Figure 31

DIP Switch Factory Reset (GMW95)

No

n-Me

tric

Td 0...2

0m

A

Cus

tom

Me

tric RH

4..

20m

A

DI

P

1 2 3 4 5 6 7 8

No

n-Me

tric

Td

Cus

tom

Me

tric RH

DI

P

1 2 3 4 5 6 7 8

GMW93

GMW94

0...5

V

0...1

0V

1

ON

2 3 4 5 6 7 8

1

ON

2 3 4 5 6 7 8

1

ON

2 3 4 5 6 7 8

Modbus

BACnet

Parity Even

A B C

Parity None

Baud

Rate

Metric

Non-Metric

Advertising