Programming - changing audible alarm volume -10, Kpm ii monitor operation – Kinze 3200 Wing-Fold Planter Rev. 7/14 User Manual

Page 100

Advertising
background image

M0241-01

Model 3200

6-10

6/11

TM

KPM II Monitor Operation

FIELD AREA/TOTAL AREA

Each AREA FIELD/TOTAL key press alternates between field area and total area.

Field area displays total number of acres or hectares using a 6 digit, one decimal place format.

NOTE: When FIELD AREA is selected, the UP or DOWN key must be held in slightly longer than normal so monitor will not mistake

this action with a CLEAR, which consists of the UP and DOWN arrow keys pressed simultaneously. A beep will sound when the

function activates.

Total area displays total number of acres or hectares using a 6 digit, one decimal place format. The total area counter updates every time

the field area counter increments. Clearing total area counter will also clear field area counter.

When the monitor is programmed as a rear only or rear/front configuration and shaft rotation sensors are installed, pressing UP arrow to

move beyond row spacing lights an arrow on an unlabeled area above ROW SPACING. This is the automatically set division line between

L.H. shaft sensor and R.H. shaft sensor. The display shows first row on rear section and front section assigned to R.H. shaft rotation sensor.

ExAMPLE: On a 12 Row 30" planter with Interplant Package, the display appears as follows:

THIS DISPLAY IS NOT ACCESSIBLE ON LEFT/RIGHT CONFIGURATIONS OR SYSTEMS WITHOUT SHAFT ROTATION SENSORS.

PROGRAMMING - CHANGING AUDIbLE ALARM

VOLUME

STEP 1 To enter programming mode, press and hold the

SETUP key. The monitor emit s several short beeps,

followed by a long beep. On the lower LCD, the

SETUP icon turns on and the arrow head icon will

flash, indicating that the user can select an item to

program.

NOTE: Monitor must be in a programmable function (row

spacing, units, speed, volume or area) to enter setup. The

monitor will not enter setup in seed population or seed

spacing.

STEP 2 Press UP or DOWN arrow keys to move the flashing

arrow to VOLUME. As the arrow icon moves, the

lower LCD displays the current setting of the selected

item.

STEP 3 Press the OK key and the flashing arrow becomes

solid and the audible alarm will sound.

NOTE: The lower LCD displays the current volume and the

SPEAKER icon is turned on. Settings are from 0 to 9.

•Use UP or DOWN arrow keys to change the setting.

With every UP arrow key push, the alarm will

increment by one step between the minimum and the

maximum. If the maximum level (9) is reached the

volume rolls over to the minimum level (0).

•Pressing the DOWN arrow key lowers the volume

until the minimum level (0) is reached, at which point

the volume rolls over to the maximum level (9).

STEP 4

To exit without saving, press and release the OK key.

The monitor restores the lower LCD to show the item

setting and the arrow icon flashes, allowing the user

to select another item to program.

To exit and save, press and hold the OK key. The

monitor emits several short beeps and SAVE? icon

is turned on. After a short time a long beep is heard,

and the lower LCD displays “DONE”. Release the OK

key. If the OK key is released BEFORE “DONE” is

displayed, changes WILL NOT BE SAVED. “DONE”

MUST be displayed in order for the save to have

occurred.

NOTE: Programming mode may be exited at any time,

by pressing the SETUP key. Pressing this key returns the

monitor to its normal operation. All items changed and

saved will come into effect immediately. Any items changed,

but not saved will revert to the original programmed value.