KPM II Monitor Operation

PROGRAMMING - UNITS (METRIC OR ENGLISH)

STEP 1 Press and hold SETUP key to enter programming

mode. The monitor emits several short beeps,

followed by a long beep. On the lower LCD, the

SETUP icon turns on and the arrow head icon will

flash, indicating that the user can select an item to

program.

NOTE: The monitor must be in a programmable function

(row spacing, units, speed, volume or area) to enter setup.

The monitor will not enter setup in seed population or seed

spacing.

STEP 2 Press UP or DOWN arrow keys to move the flashing

arrow to UNITS. As the arrow icon moves, the lower

LCD will display the current setting of the item

selected.

STEP 3 Press the OK key and the flashing arrow becomes

solid and audible alarm sounds.

NOTE: Lower LCD alternately displays Metric or English

icons, indicating Metric or English mode.

•Use UP or DOWN arrow keys to change the setting.

STEP 4 Press and release the OK key to exit without saving.

The monitor restores lower LCD to show item setting,

and the arrow icon flashes, allowing user to select

another item to program.

Press and hold OK key to exit and save. The monitor

emits several short beeps and SAVE? icon is turned

on. After a short time a long beep is heard, and the

lower LCD displays “DONE”. Release the OK key. If

the OK key is released BEFORE “DONE” displays,

changes WILL NOT BE SAVED. “DONE” MUST be

displayed for the save to have occurred.

NOTE: Programming mode may be exited at any time, by

pressing the SETUP key. Pressing this key returns the

monitor to its normal operation. All items changed and

saved come into effect immediately. Any items changed, but

not saved revert to original programmed value.

PROGRAMMING - ROW SPACING

STEP 1 Application mode (rear/front, left/right or four sections)

must be active before entering programming mode. If

monitor is programmed in a rear/front configuration,

both sections are active (alternating every 5 seconds

if the SMM console is not used). You can then set row

spacing to Interplant

System row spacing.

EXAMPLE: On a 12 Row 30" with Interplant Package

set row spacing to 15.0 with front active.

When monitor is in normal field operation mode,

disabling front section automatically changes row

spacing to 30".

STEP 2 To enter programming mode, press and hold SETUP

key. Monitor will emit several short beeps, followed

by a long beep. On lower LCD, the SETUP icon turns

on and arrow head icon will flash, indicating that user

can select an item to program.

NOTE: Monitor must be in a programmable function (row

spacing, units, speed, volume or area) to enter setup. Monitor

will not enter setup in seed population or seed spacing.

STEP 3 Press UP or DOWN arrow keys to move flashing

arrow to ROW SPACING. As arrow icon moves, lower

LCD displays current setting of selected item.

STEP 4 Press OK key and flashing arrow becomes solid and

the audible alarm sounds.

NOTE: Lower LCD displays current row spacing (in inches or

centimeters) and ROW SPACING icon is turned on.

•Least significant digit of displayed value blinks.

•This value can be changed by pressing UP or

DOWN arrow keys.

•Once digit is correct, press MODE SELECT key and

blinking digit moves to next significant digit, where

process can be repeated.

NOTE: Monitor limits entry of row spacing from 10.0 inches

(25.4 cm) to 99.9 inches (253.7 cm). If monitor is configured to

a rear/front configuration, limits change to a minimum of 5.0

inches (12.7 cm) and a maximum of 49.9 inches (126.8 cm).

STEP 5

To exit without saving, press and release OK key.

Monitor restores lower LCD to show setting of the

item and arrow icon will flash, allowing user to select

another item to program.

To exit and save, press and hold OK key. Monitor will

emit several short beeps and SAVE? icon is turned

on. After a short time a long beep is heard, and lower

LCD will display the word “DONE”. Release OK key.

If OK key is released BEFORE the word “DONE” is

displayed, changes WILL NOT BE SAVED. The word

“DONE” MUST be displayed in order for the save to

have occurred.

To exit setup mode, press SETUP key.

NOTE: Programming mode may be exited at any time, by

pressing SETUP key. Pressing this key will return monitor to

its normal operation. All items changed and saved will come

into effect immediately. Any items changed, but not saved

revert to original programmed value.