KPM I Monitor Operation

STEP 6 When all the seed tubes w/sensors for the current

section are installed, check to be sure the monitor

displays solid numbers for the number of sensors

connected.

®

STEP 7 If this condition is satisfied, press and hold the OK

key to save the setup for the current section. The

SAVE? icon shows followed by continuous short

beeps indicating monitor is preparing to save. The

installer has 5 seconds to decide to save the current

configuration. During this time the short beeps

will sound. To complete the save, hold the OK key

pressed until the word “DONE” shows on the screen

followed by a long beep and the SAVE? icon turns off.

When the OK key is released the monitor continues

with the second section installation.

®

®

NOTE: Individual seed tubes may be unplugged for special

situations. An alarm sounds which can be silenced by

touching the OK key. The monitor recognizes each seed tube

when reconnected.

®

STEP 8 Follow STEPS 5 through 7 to install the second

section. If no seed tubes are installed on the

second section, press and hold the OK key until

“DONE” shows on the screen followed by a long

beep and the SAVE? icon turns off.

®

See “KPM I/KPM II Stack-

Mode Electronic Seed Monitor

Troubleshooting” in the

Troubleshooting section of this

manual.