Programming - speed -12, Kpm ii monitor operation – Kinze 3200 Wing-Fold Planter Rev. 7/14 User Manual

Page 102

Advertising
background image

M0241-01

Model 3200

6-12

6/11

TM

KPM II Monitor Operation

PROGRAMMING - SPEED

STEP 1 Press and hold SETUP key to enter programming

mode. Monitor emits several short beeps, followed

by a long beep. On the lower LCD, the SETUP icon

turns on and the arrow head icon will flash, indicating

the user can select an item to program.

NOTE: Monitor must be in a programmable function (row

spacing, units, speed, volume or area) to enter setup. The

monitor will not enter setup in seed population or seed

spacing.

STEP 2 Press UP or DOWN arrow keys to move flashing

arrow to SPEED. As arrow icon moves, lower LCD

displays selected item current setting.

STEP 3 Press the OK key and the flashing arrow becomes

solid and the audible alarm will sound. The R.H. digit

on the display will be blinking.

The speed constant is used to record how many

pulses are generated per mile (or kilometer) from the

ground speed sensor. The lower LCD will display the

current pulses per mile (or kilometer) using a 6 digit,

no decimal place format. The PULSES per MILE (or

PULSES per KM) icons are turned on.

NOTE: It is highly recommended that a field calibration be

done to establish the PPM/PPKM (Pulses Per Mile/Kilometer)

number on a new machine installation. Several factors can

affect this value such as wheel slip on the magnetic distance

sensor, mounting angle and height on the radar distance

sensor, etc. IT IS NOT UNCOMMON FOR THE SPEED ON

THE MONITOR TO VARy SLIGHTLy FROM THE TRACTOR

SPEEDOMETER. Adjusting PPM/PPKM in the monitor to

make speed agree can cause serious errors in acre/hectare

and population counts. Do field checks to verify populations

and seed spacings.

NOTE: Monitor defaults to 500 PPM (310 PPKM) on new

system installations. This must be changed to obtain

accurate readings.

• In field conditions, measure 330 feet (

1

/

16

mile) or

100 meters, depending on the unit of measurement

selected.

• Pull the tractor up to the starting line.

• Press UP and DOWN arrow keys at the same time

and hold them down until CLEAR? icon displays and

monitor beeps several times. Monitor emits a long

beep and number of pulses is cleared.

NOTE: If the PPM/PPKM number starts to count pulses with

the tractor not moving, check the radar for vibration or other

kinds of interference.

• Drive the tractor for 330 feet (1/16 mile) or 100 meters

and stop.

• The monitor will count the number of pulses and

display them.

STEP 4 To exit without saving, press and release the OK

key. The monitor will restore the lower LCD to show

the previous setting of the item, and the arrow icon

will flash, allowing the user to select another item to

program.

To exit and save, press and hold the OK key. The

monitor emits several short beeps and SAVE? icon

is turned on. After a short time a long beep is heard,

and the lower LCD displays “DONE”. Release the OK

key. If the OK key is released BEFORE “DONE” is

displayed, changes WILL NOT BE SAVED. “DONE”

MUST be displayed for save to have occurred.

NOTE: Programming mode may be exited at any time by

pressing the SETUP key. Pressing this key returns monitor

normal operation. All items changed and saved come into

effect immediately. Any items changed, but not saved revert

to original programmed value.

Advertising