174

Firmware Version 5.2

Press: Map button > Meter RPM button > Planter Drives > Prime Seed Meter button

A message displays, stating “Seed Meter Prime in Progress.” While this message displays, the seed
meter will turn one (and only one) revolution automatically. When complete, return to the Seed Rate
Planter Control screen.

C

ALIBRATING

S

EED

R

ATE

M

ETERS

The Meter Calibration number allows the seed meter to communicate the correct seed population to the
display. Assuming the Controller Settings are correct for the seed rate, this Meter Calibration number,
which is based on the number of cells on the seed meter, should not need to be adjusted. However, you
may wish to recalibrate after changing seed types and treatments. Recalibrate if the as-applied seed
rate does not match the population shown on the planter monitor.

Notes:

• The seed rate meter calibration does not recalibrate any previously-logged planting data.

• This recalibration number applies to a specific crop type, i.e., corn. Normally, there is no need to

recalibrate when switching varieties within the same crop type.

• Make sure seed meter is primed. For more information, See

“Priming Seed Rate Meters”

above.

Press: Map button > Settings button > Planter Drives tab > Calibrate button

or

Press: Map button > Meter RPM button > Planter Drives > Calibrate button

1. Acknowledge the Warning

Acknowledge this warning by pressing

.

2. Select Drive to Calibrate

The Meter Calibration Wizard appears. Select the drive to calibrate. Press

to continue.

3. Enter Simulated Ground Speed

Enter the simulated ground speed for the calibration procedure. Press

to continue.

4. Enter Simulated Target Rate

Enter the simulated target rate of the calibration procedure. Press

to continue.

5. Press Start

Press the green-colored Start button to begin dispensing the seed.

6. Dispensing Seed

The seed meter turns for five revolutions. As the seed meter dispenses seed, the button will change its color
to red, and a message displays that the seed dispensation is in process.

Settings

Planter Drives

Calibrate

Planter Drives (rpm)

1

70

Planter Drives

Calibrate

Advertising