• Max Metering Speed
Setting determines the maximum RPM of the metering shaft that controls product distribution to the
application point. This setting is used when controlling a granular strip-till toolbar.

Strip Till Control: PWM Control Valve

• PWM Frequency
The frequency that the PWM control valve is pulsed at.
Settings can be found from the manufacturer of the
valve. Typical settings range from 100-125 Hz. The
default setting is 100.

• PWM Gain
Determines how aggressively the control valve responds
when making rate changes. The higher the value the
more aggressive the system response is. The default
setting is 100.

• Zero Flow Offset
Represents the maximum duty cycle that is sent to the
control valve without producing any hydraulic flow from

the PWM valve. Using too high of a Zero RPM Offset value can cause the conveyor to not properly shut off.
See the PWM valve manufacturer information for recommended settings. The default setting is 30.

• Allowable Error
Determines the percent of error that is allowed prior to the product control system making any flow rate
changes. 2% - 3% is the normal dead band setting range.

- Too low of a setting value can cause the product control system to continually hunt for the target

application rate.

- Too high of a setting will cause excessive product application error.

• Shaft Speed Calibration
Calibration number representing the pulses that equal one revolution of the rate control metering system.

• Max Metering Speed
Setting determines the maximum RPM of the metering shaft that controls product distribution to the
application point. This setting is used when controlling a granular strip-till toolbar.

Linear Actuator/Clutch Settings

Note: When using Linear Actuator Control, the system requires the Control Valve Configuration on all three
channels to be set the same.

Strip Till Control

Channel 1

Channel 2

Channel 3

Auxiliary

Control Valve Configuration

PWM

PWM Frequency

100

PWM Gain

100

Zero Flow Offset

30

Allowable

Error

2 %

Shaft Speed

Calibration

180 pls/rev

Max Metering

Speed

100 rpm