Bridge module, Troubleshooting claas quantimeter configurations, Claas q – Kinze Ag Leader Integra User Manual

Page 341: Roubleshooting, Uantimeter, Onfigurations, Arvest, Laas

Advertising
background image

325

H

ARVEST

C

LAAS

Q

UANTIMETER

Notes:

• The Grain Harvest Diagnostics screen
displays different information than the
Diagnostics screen that appears for other
Harvest configurations. This information is
relayed from the CEBIS monitor.

For specific information regarding
settings shown on this screen, contact
Technical Support.

Bridge Module

The Bridge Module routes communication between

• (A) CAN-Bus

• (B) ParaDyme CAN-Bus

• (C) CLAAS CAN-Bus

Three indicator lights verify communication received from
these systems. A green light indicates good communication;
an amber light indicates no communication.

When the Bridge Module is communicating
with the display, it should appear on the
display’s Devices list. (For more information
on Device Information, see

“Device

Information” on page

77

).

T

ROUBLESHOOTING

CLAAS Q

UANTIMETER

C

ONFIGURATIONS

During the operation of a CLAAS Quantimeter field operation configuration, you may see the following
error messages. Below is a table describing the cause and solution of the error messages that could
appear.

Error Message: Warning: “Full header width doesn’t match Quantimeter full header width”

Possible Cause: The full header width that was specified in the display’s Header Setup Wizard does

not match the header width in the CEBIS monitor.

Solution: Set the swath width in the CEBIS monitor to match the swath width of the

operating configuration in the display.

Error Message: Crop Type Changed: “The current configuration is no longer valid”

Cal Factor
Moisture

Temperature

Header
Ground Speed
Density
Header Width

Active Width

Grain Type

1.35

18.6 %

73.4 F

Down

5.5 mph

60 lb/bu

29.9 ft
29.9 ft

3

Engine Hours
Threshing Status
Separator Hours
Chopper Hours

Total Fuel
Total Fuel (Field)
Total Fuel (Road)
Active Segments

Engine Speed

1395.6

OFF

1250.5

1248.2

290.6 gal
178.3 gal

112.3 gal

10

1112 rpm

Header Segments
Total Distance
Distance (Field)
Distance (Road)
Total Yield
Total Yield (Dry)
Fuel Rate

Calibration Flow
Header Pos

10

182168.6 ft

164042 ft

18126.6 ft

1090.7 T
1019.9 T

2.6 gal/h

2058.4 bu/h

25 %

Grain Harvest Diagnostics

Firmware:

Firmware ID:

Hardware ID:

Serial Number:

Revision:

Run Time:

Boot Counter:

1.0.15

AL BRIDGE

4001826

2009010001

1.255.255.255

34209

212

Devices

DISPLAY

207 AL BRIDGE

Diagnostics