Injection diagnostics, Troubleshooting direct injection configurations, Njection – Kinze Ag Leader Integra User Manual

Page 269: Iagnostics, Roubleshooting, Irect, Onfigurations, Pplication

Advertising
background image

253

A

PPLICATION

I

NJECTION

• (A) Mapping Toolbox

• (B) Product Control Toolbox

• (C) Injection Controls button

• (D) NORAC UC5 Boom Height Control
Options button

• (E) Section Indicators

• (F) NORAC UC5 Engage button

• (G) AutoSwath

• (H) Master Switch Status (on)

• Injection Controls button (C)
The number of direct injection controllers appear within the Injection Control button. This button displays
green for each injection module when detecting flow. Press the Injection Controls button to Prime or Agitate
the Injection pump.

I

NJECTION

D

IAGNOSTICS

The Injection Diagnostics screen provides raw values from sensors verifying that the
pump’s output is working. To go to the Injection Diagnostics screen, press on the Device
Information button. At the Devices screen, highlight the item marked AL Direct Inject then

press the Diagnostics button. The Injection Diagnostics screen appears. In addition to the Controller’s
Name and Serial Number, it provides the following information:

• Digital Pump Speed
Displays volume information, shown in Hz.

• Analog Pump Speed
Displays varying voltage as pump speed is increased or
decreased.

• Discharge Flow Monitor
Displays information showing that flow is being
discharged for every piston stroke.

• Flow/Speed Sensor Ratio

The ratio that the system derived for calibration.

T

ROUBLESHOOTING

D

IRECT

I

NJECTION

C

ONFIGURATIONS

When controlling a chemical injection pump using the Injection Module PN: 4000896, the configuration
requires the use of a Liquid Module PN: 4000394. The injection control is based off of the vehicle that
has been configured for the liquid DirectCommand control channel. Once configured, the Injection pump
uses the same switch inputs and ground speed input that has been configured for the liquid system.

1

205 +
185 - 205

165 - 185
145 - 165

0 - 145

Rate

Pressure (PSI)

Main:

Agitation:

37

45

Flow:

Container:

12.0 gal/min

793 gal

Mode: Crop

Target Height: 12 in

Sensitivity: 5

12.0

12.0

15.5

50F

Injection

1

0.49

ac

5.0

mph

15.00

15.00

5.000

5.000

gal/ac

lb/ac

1

15

2

10

30% UAN

N

Controller Name

Serial Number

Digital Pump Speed (Hz)

Analog Pump Speed (V)

Discharge Flow Monitor (Hz)

Flow/Speed Sensor Ratio

Di

2008850060

67.0

7.2

9.9

0.0

Injection Diagnostics