288

Firmware Version 5.2

(You must make sure to account for sprocket ratios if chain driven).

3. Check the user-defined value found under the controller settings for Strip-Till.

4. The CFR number may need to be adjusted.

T

ROUBLESHOOTING

S

ERIAL

C

ONTROL

A

PPLICATIONS

Problem: Rate changes on the display, but not on the controlled console.

Solution:

1. Verify the current firmware is running on the display and Application Rate module.

2. Check the settings specific to your controlled console. (For more information, refer to the Quick

Reference Guide).

3. Check cabling and all connections.

4. Disconnect the serial connection and determine if the controller is functioning properly without

the display.

Problem: The display rate and serial-controlled rate do not match.

Solution:

1. Verify the current firmware is running on the display and Application Rate Module.

2. Check to make sure the nominal rate in the display matches the nominal rate in the serial-

controlled console.

Driven Teeth

X Rate Sensor Pulses = True Pulses

Drive Teeth