Crop sensor setup, Corn settings, North american wheat settings – Kinze Ag Leader Integra User Manual

Page 276: Europe settings, Ensor, Etup

Advertising
background image

260

Firmware Version 5.2

C

ROP

S

ENSOR

S

ETUP

Corn Settings

The Crop Sensor Setup screen is where you can adjust the rate displayed on the Map screen Equipment
Tab’s VI Bar Graph. You can access the Sensor Setup screen in one of two ways:

Press: Home button > Setup (wrench) button > Configuration (tractor) button > Configuration tab > your
specific configuration > Setup (wrench) button > Crop Sensor button

Note: You must have a Reference Strip loaded for the Algorithm Settings button to be active. For more
information, see

“Scan a Reference Strip” on page

263

.

Corn Settings

North American

Wheat Settings

Minimum Rate - lowest amount of nitrogen operator wants applied. If OptRx prescribes a lower rate
system will default to the minimum rate.

Maximum Rate - highest amount of nitrogen operator wants applied. If OptRx prescribes a higher rate
system will default to the maximum rate.

Economic Optimal Rate - total amount of nitrogen uptake by the plant over the growing season.

N Credits - amount of nitrogen that is available to the plant in the soil from previous year’s crop and
fertilizer application.

Pre-Sidedress Rate - amount of nitrogen that has been applied in the current year before sidedressing.

North American Wheat

North American Wheat Settings

Europe Settings

Minimum Rate - lowest amount of nitrogen operator wants applied. If OptRx prescribes a lower rate
system will default to the minimum rate.

Maximum Rate - highest amount of nitrogen operator wants applied. If OptRx prescribes a higher rate
system will default to the maximum rate.

Rate Increment - increments of rate change. This setting will be in lbs. of N/ac (kg of N/ha).

Economic Optimal Rate - total amount of nitrogen uptake by the plant over the growing season.

N Credits - amount of nitrogen that is available to the plant in the soil from previous year’s crop and
fertilizer application.

Pre-Topdress Rate - amount of nitrogen that has been applied in the current year before topdressing.

Europe Settings

Minimum Rate - lowest amount of nitrogen operator wants applied. If OptRx prescribes a lower rate
system will default to the Minimum Rate.

Maximum Rate - highest amount of Nitrogen operator wants applied. If OptRx prescribes a higher rate
system will default to the Maximum Rate.

Rate Increment - increments of rate change. This setting will be in lbs. of N/ac (kg of N/ha).

Configuration

Select Your Specific

Configuration

Crop Sensor

Advertising