Calibrate pressure sensor, Down force status, Bar graphs on run screen – Kinze Ag Leader Integra User Manual

Page 200: Calibrate pressure sensor down force status, Alibrate, Ressure, Ensor, Orce, Tatus, Raphs on

Advertising
background image

184

Firmware Version 5.2

PWM Frequency

The frequency that the PWM control valve is pulsed at should be set to 200.

Calibrate Pressure Sensor (Grayed out for Monitor Only)

Pressure Sensor Enable (Grayed out for Monitor Only)

Row Unit Sensors - Sensors 1-4 check boxes. Enable or disable gauge wheel sensors.

C

ALIBRATE

P

RESSURE

S

ENSOR

(Only able to calibrate when Control Mode has been selected)

Press: Home button > Setup (wrench) button > Configuration (tractor) button > Configuration tab > your
specific configuration > Setup (wrench) button > Down Force button > Channel 1 (or Channel 2) >
Calibrate Pressure Sensor button

Setpoint - enter the current pressure of the system
found on the mechanical pressure gauge on the
valve block

Slope - pressure sensor calibration, do not adjust
this value

D

OWN

F

ORCE

S

TATUS

Press: Map button. Icons on the lower right side of Map Screen show the status of Down Force.

Active

Inactive

Manual Mode

Manual Hold

B

AR

G

RAPHS ON

R

UN

S

CREEN

Bar Graphs on Run Screen shows force on
Gauge Wheel and Down force being applied to
row unit. Press bar graph to advance to next
graph. Bar graph may also contain graphs for
Advanced Seed Monitoring.

Configuration

Select Your Specific

Configuration

Down
Force

Channel 1

Calibrate

Pressure Sensor

Pressure Sensor Calibration: Step 2 of 3

Set Point

0 PSI

Slope

0.75 PSI/mV

Enter the Setpoint and Slope for the Hydraulic Pressure Sensor

2

4

6

8

10

12

14

16

18

20

22

24

200 lb

150 lb

100 lb

50 lb

Gauge Wheel 203 lb