Kinze Ag Leader Integra User Manual

Page 234

Advertising
background image

218

Firmware Version 5.2

Once container has been configured press

to continue.

10. Enter Swath Width

Press

to enter swath width.

11. Enter Number of Boom Sections

Press

/

to enter number of boom sections.

12. Enter Boom Section Widths

Highlight specific boom section and press

to enter boom width. The total width of all boom

sections must equal swath width.

13. Enter Application Point Offset

Press

to enter distance from hitch to application point (front to back). Press

to accept

value on offset screen. Press

to accept value for the application point.

Note:

If setting up a Self-Propelled Applicator, enter the distance from rear axle to application point.

Use drop-down menu to select distance Behind or In Front.

Note:

At this point additional functionality can be added to the implement, such as direct injection.

If no additional functionality is being added, press

to continue.

14. Add Additional Devices (optional)

Press

to add boom control functionality.

Press

to add boom sensor functionality.

• Press

to enter sensing width (defaults to implement width, change only if necessary).

• Use

/

to enter number of sensors.

• Press Swath Offsets button to enter offsets. System can not be configured with sensors and application

point on opposite sides of the hitch.

Press

to continue.

15. Enter Hitch Point Offsets

Press check box if implement provides a hitch point. Press

to enter distance and drop-down

menu to enter “to the left” or “to the right”. Press

to enter distance Forward or Backward. Press

to continue.

16. Enter Implement Name

Press

to enter a name for the implement. Press

to continue.

Norac UC5

OptRx Crop Sensor

Advertising