296

Firmware Version 5.2

• Actuator Response 1
Determines the speed of the actuator when product
control error exceeds the Response Threshold setting.
Represents the fast speed of the actuator. Decreasing
the value will cause the actuator to run slower. The
default setting is 90%.

• Actuator Response 2
Determines the speed of the actuator when product
control error is less than the Response Threshold
setting. Represents the slow speed of the actuator.
Decreasing the value will cause the actuator to run
slower. The default setting is 18%.

• Response Threshold
Determines where the control channel switches between
using Actuator Response 1 and Actuator Response 2
speed settings. Leaving all other actuator control
settings at the default value and making a small
adjustment to this setting is usually all that is required to
fine-tune system performance. The default setting is 4.

- Decreasing this value will have the overall effect of
speeding up actuator response.

- Increasing this value will have the overall effect of
slowing actuator response.

• Allowable Error
Determines the percent of error that is allowed prior to

the product control system making any flow rate changes. 2% - 3% is the normal dead band setting range.

- Too low of a setting value can cause the product control system to continually hunt for the target

application rate.

- Too high of a setting will cause excessive product application error.

• Shaft Speed Cal
Calibration number representing the pulses that equal one revolution of the rate control metering system.

• Max Conveyor Speed
Setting determines the maximum RPM of the conveyor that controls product distribution to the application
point.

• Actuator/Clutch Configuration
Selecting one of the three available actuator/clutch settings: [Single Bin Actuator], [Multiple Bin Actuator,
Main Only], [Multiple Bin Actuator, Main + Channel] from the Control Valve Configuration drop-down menu
(above) determines specific behavior of the actuators/clutches on zero rate.

Strip Till Control

Channel 1

Channel 2

Channel 3

Auxiliary

Control Valve Configuration

Single Bin Actuator

Allowable

Error

2 %

Shaft Speed

Calibration

180 pls/rev

Max Metering

Speed

100 rpm

Actuator

Response 1

90 %

Actuator

Response 2

18 %

Response
Threshold

4

Channel 1

Channel 2

Channel 3

Control Valve Configuration

Auxiliary

Single Bin Actuator

Servo

PWM

Single Ben Actuator

Multiple Bin Actuator, Main Only

Multiple Bin Actuator, Main + Channel

Allowable

Error

2 %

Shaft Speed

Calibration

180 pls/rev

Max Metering

Speed

100 rpm

Strip Till Control