Possible Cause: The display has detected that the crop type specified in the CEBIS monitor has

changed to a crop type that is different than what is specified in the display’s field operation
configuration.

Either:

Solution: 1. Change the crop type specified in the CEBIS monitor back to what is specified

in the display. Then reload the display’s field operation configuration.

Or

Solution: 2. Create a new field operation configuration that includes the new crop type. If

necessary, create a new Harvest Product in Product Setup with the Harvest Crop Wizard.
For more information, see

“Grain Harvest Settings” on page

27

.

Error Message: Grain Calibration: “A new grain calibration has been detected. Select an operating

configuration to continue.”
Possible Cause: When a new calibration is started in the CEBIS monitor, the warning at left

appears on the display. At the same time, the display unloads the Field Operating Configuration
that was collecting data with the old calibration.

Solution: Acknowledge the warning by pressing

. At the Home screen, press the

Select Event button. Use the Field Operation Wizard to create a new field operation
configuration. After receiving the new calibration from the CEBIS monitor, the display will
calculate that field operation configuration’s harvest data by using this new calibration
that was sent from CEBIS. (Also discussed in

“Calibration Information” on page

322

).

Error Message: CLAAS Communication Error: “Cannot communicate with CLAAS bridge module.”

Possible Cause: No communication between Bridge Module and CLAAS CAN-Bus. (Shown as

Indicator Light C on Bridge Module in

“Bridge Module” on page

325

).

Solution: Check cabling between Module and CLAAS Can-Bus.

Error Message: CAN Node Lost: “AL Bridge Node has stopped communicating.”

Possible Cause: No communication between Bridge Module and display. (Shown as Indicator Light

A on Bridge Module in

“Bridge Module” on page

325

).

Solution: Check cabling between Bridge Module and display.