Troubleshooting serial control applications, Roubleshooting, Erial – Kinze Ag Leader Integra User Manual

Page 321: Ontrol, Pplications

Advertising
background image

305

A

PPLICATION

S

TRIP

T

ILL

Problem: AutoSwath turns on the booms too fast or too slow.

Solution: Check GPS offsets in the vehicle setup to verify all of the measurements are

correct.

Problem: AutoSwath feature is not shown

Solution: The display must have the AutoSwath feature password-unlocked before the

feature is available to the operator.

Problem: AutoSwath is checked on, but the spreader will not turn on.

1. Make sure the ground speed is registering a value greater than zero on the display.

2. Make sure the applicator is inside of the field boundary.

Problem: Conveyor turns off in the middle of the pass

Solution: Check the display firmware and module firmware to see if they are running the

latest version.

Problem: Total Applied does not match Actual Weight Applied

Solution:

1. Make sure the shaft speed pls/rev are set correctly in the controller settings.

2. Make sure the controlling product is set to the correct units.

Problem: Rate not responding

Solution:

1. Make sure there is a ground speed registering on the display.

2. Make sure the shaft speed pls/rev are set correctly in the controller settings.

(You must make sure to account for sprocket ratios if chain driven)

3. Check the user-defined value found under the controller settings for Strip-Till.

4. The CFR number may need to be adjusted.

T

ROUBLESHOOTING

S

ERIAL

C

ONTROL

A

PPLICATIONS

Problem: Rate changes on the display, but not on the controlled console.

Solution:

1. Verify the current firmware is running on the display and Application Rate module.

2. Check the settings specific to your controlled console. (For more information, refer to the Quick

Reference Guide).

3. Check cabling and all connections.

4. Disconnect the serial connection and determine if the controller is functioning properly without

the display.

Problem: The display rate and serial-controlled rate do not match

Solution:

1. Verify the current firmware is running on the display and Application Rate Module.

2. Check to make sure the nominal rate in the display matches the nominal rate in the serial-

controlled console.

Driven Teeth

X Rate Sensor Pulses = True Pulses

Drive Teeth