5 communication times, 1 processing time in the basic unit, 2 number of devices connected to the bus – Lenze EMF2141IB User Manual

Page 13: Processing time in the basic unit, Number of devices connected to the bus, Technical data

Advertising
background image

Technical data

3-3

L

BA2141 EN 1.0

3.5

Communication times

The communication times depend on

the data transmission time which depends on
– the baud rate
– the user-data length

the processing time in the basic unit (see the following chapter)

Tip!

You will find more information about the data-transfer time in the documentation for your host
system.

3.5.1

Processing time in the basic unit

The processing time in the basic unit starts when a message arrives at the fieldbus module (action)
and ends with the response of the basic unit to this message.

Processing time 820X

Action

Processing step

Max. time required by the controller

Writing of control word or setpoint, if the
value has changed

Writing of status word and actual
value

200 ms

+40 ms tolerance

Alternating reading of status word and

Control word or setpoint reading

27 ms

+48 ms Toleranz

g

g

actual value

Control word and setpoint reading

54 ms

+56 ms tolerance

Processing of parameter access if there

Read parameter

55 ms

+48 ms tolerance

g

p

is a service

Parameter writing

108 ms

+32 ms tolerance

Tab. 3-1

Processing time: 820X

Processing time: 821X / 8200 vector / 822X

Parameter data and process data are independent of each other.

Parameter data: 30 ms + 20 ms tolerance

Process data: approx. 3 ms + 2 ms tolerance

Processing time: 9300 servo inverter

Parameter data and process data are independent of each other.

Parameter data: approx. 30 ms + 20 ms tolerance (typical)
– The processing time can be longer for some codes

(see 9300 Manual).

Process data: approx. 3 ms + 2 ms tolerance

Processing time: Drive PLC / 9300 Servo PLC

Parameter data and process data are independent of each other.

Parameter data: approx. 30 ms + 20 ms tolerance

Process data depend on the process image.
The process image is an update of process data made after every task cycle.

3.5.2

Number of devices connected to the bus

The maximum bus size depends on

the baud rate used

the number of repeaters

For more detailed information see the documenation for the control system.

Show/Hide Bookmarks

Advertising