2 control word for 8200 vector, Control word for 8200 vector, Parameter setting – Lenze EMF2141IB User Manual

Page 55: 1 status word for 82xx, Show/hide bookmarks

Advertising
background image

Parameter setting

6-33

L

BA2141 EN 1.0

6.5.2.1

Status word for 82XX

Bit

820X

821x,822x

00

Actual parameter set

0 = Parameter set 1 or 3 active

1 = Parameter set 2 or 4 active

Actual parameter set

0 = Parameter set 1 or 3 active

1 = Parameter set 2 or 4 active

01

IMP (pulse inhibit)

0 = Pulses for power stage enabled

1 = Pulses for power stage inhibited

IMP (pulse inhibit)

0 = Pulses for power stage enabled

1 = Pulses for power stage inhibited

02

I

max

(current limit reached)

0 = Current limit not reached

1 = current limit reached

I

max

(current limit reached)

0 = Current limit not reached

1 = current limit reached

03

not assigned

f

d

= f

dset

0 = f

d

f

dset

1 = f

d

= f

dset

04

f

d

= f

dset

0: f

d

f

dset

1: f

d

= f

dset

RFG on = RFG off

0 = RFG on

RFG off

1 = RFG on = RFG out

05

Qmin (f

d

f

dQmin

)

0 = Qmin not active

1 = Qmin active

Qmin (f

d

f

dQmin

)

0 = Qmin not active

1 = Qmin active

06

f

d

= 0 (act. frequency = 0)

0: f

d

0

1: f

d

> 0

f

d

> 0 (actual frequency value = 0)

0 = f

d

0

1 = f

d

> 0

07

Ctrl. inhibit (controller inhibit)

0 = controller not inhibited

1 = controller inhibited

Ctrl. inhibit (controller inhibit)

0 = controller not inhibited

1 = controller inhibited

08...11

Controller status

0 = Controller initialization

8 = Error active

Controller status

0 = Controller initialization

1 = Switch on inhibit

3 = Operation inhibited

4 = Flying-restart circuit active

5 = DC brake active

6 = Operation enabled

7 = Message active
8 = Error active

12

Overtemperature warning

0 = No warning

1 = Warning

Overtemperature warning

0 = No warning

1 = Warning

13

U

Gmax

(DC-bus overvoltage)

0 = No overvoltage

1 = overvoltage

U

Gmax

(DC-bus overvoltage)

0 = No overvoltage

1 = overvoltage

14

Direction of rotation

0 = CW rotation

1 = CCW rotation

Direction of rotation

0 = CW rotation

1 = CCW rotation

15

Ready

0 = not ready for operation

1 = ready for operation

Ready

0 = not ready for operation

1 = ready for operation

Show/Hide Bookmarks