1 status word for 82xx, Status word for 82xx, Parameter setting – Lenze EMF2141IB User Manual

Page 49

Advertising
background image

Parameter setting

6-27

L

BA2141 EN 1.0

6.4.2.11

Receive heartbeat for AIF-CTRL

network input config SNVT_state nciAIFRecHrtBt;

Here you can select the manufacturer-specific network variables (

nviAIFStw

,

nviAIFIn1

,

nviAIFIn2

,

nviAIFIn3

) which are to be monitored with a

Receive Timeout

.

nciAIFRecHrtBt.bit0

= 0 – No timeout monitoring for

nviAIFStw

nciAIFRecHrtBt.bit0

= 1 – Timeout monitoring for

nviAIFStw

nciAIFRecHrtBt.bit1

= 0 – No timeout monitoring for

nviAIFIn1

nciAIFRecHrtBt.bit1

= 1 – Timeout monitoring for

nviAIFIn1

nciAIFRecHrtBt.bit2

= 0 – No timeout monitoring for

nviAIFIn2

nciAIFRecHrtBt.bit2

= 1 – Timeout monitoring for

nviAIFIn2

nciAIFRecHrtBt.bit3

= 0 – No timeout monitoring for

nviAIFIn3

nciAIFRecHrtBt.bit3

= 1 – Timeout monitoring for

nviAIFIn3

If one of the monitored variables gets a

Receive Heartbeat Timeout

, the function selected in

nciAIFDefStw

will be carried out.

Input range

The possible range for the input variable is 0 or 1 for every bit.

Only bits 0 and 3 will be evaluated.

Standard value

0