Parameter setting – Lenze EMF2141IB User Manual
Page 61
![background image](/manuals/566037/61/background.png)
Parameter setting
6-39
L
BA2141 EN 1.0
6.5.3.2
Control word for 8200 vector
Bit
8200vector
Bit
Default setting:
C0001=3 if C0007 < 52
Default setting:
C0001=3 if C0007 > 51
00,
00 = C0046 active
01 = NSET1-JOG1 (C0037) active
00,
01
01 NSET1 JOG1 (C0037) active
10 = NSET1-JOG2 (C0038) active
11 = NSET1-JOG3 (C0039) active
Freely configurable by user
02
DCTRL1-CW/CCW
0 = not active
1 = active
y
g
y
03
AIF-CTRL-QSP
0 = not active
1 = active
04
NSET1-RFG1-STOP
0 = not active
1 = active
05
NSET1-RFG1-0
0 = not active
1 = active
06
MPOT1-UP
0 = not active
1 = active
Freely configurable by user
07
MPOT1-DOWN
0 = not active
1 = active
08
Freely configurable by user
09
AIF-CTRL-CINH
0 = not active
1 = active
10
AIF-CTRL-TRIP-SET
0 = not active
1 = active
11
AIF-CTRL-TRIP-RESET
0 -> 1 = Edge from 0 to 1
12
DCTRL1-PAR2/4
0 = not active
1 = active
13
DCTRL1-PAR3/4
0 = not active
1 = active
Freely configurable by user
14
MCTRL1-DCB
0 = not active
1 = active
15
Freely configurable by user
Show/Hide Bookmarks