12 monitoring reaction for aif-ctrl, Monitoring reaction for aif-ctrl, Parameter setting – Lenze EMF2141IB User Manual

Page 44

Advertising
background image

Parameter setting

6-22

L

BA2141 EN 1.0

6.4.2.6

Minimum speed

network input config SNVT_lev_percent nciMinSpeed;

The configuration variable contains the minimum motor speed. The value is indicated as percentage
of the rated value (

nciNmlSpeed

).

Input range

The possible bandwidth for the configuration variable is between –163.840% and 163.830%
(resolution 0.005% ). The value +163.835% (7FFF

hex

) is assumed to be wrong.

The entered value will be checked by means of the following formula:

–163.840%

Minimum speed

£

Maximum speed

163.830%

If the result is wrong, the lower value is taken as minimum speed.

Standard value

0.000 %

Function

After a change of the minimum speed, the value will be sent to the drive via the parameter channel
(code 0010, subcode 00).

SCPT Reference

SCPTminSetpoint (53)