Parameter setting

6-42

L

BA2141 EN 1.0

Signal configuration (L-C0005)

AIF-OUT.W1

AIF-OUT.W2

AIF-OUT.W3

AIF-OUT.D1

Speed control

1003/1013/1113

MCTRL-NACT

Actual speed

100 % = 16383

MCTRL-MSET2

Torque display

100 % = 16383

MCTRL-NSET2

Speed controller input

100 % = 16383

Torque control

4003/4013/4113

MCTRL-MSET2

Torque display

100 % = 16383

MCTRL-NACT

Act. speed in %

100 % = 16383

MCTRL-NSET2

Speed controller input

100 % = 16383

DF master

5003/5013/5113

MCTRL-NACT

Actual speed

100 % = 16383

MCTRL-MSET2

Torque display

100 % = 16383

MCTRL-NSET2

Speed controller input

100 % = 16383

DF-slave bus

6003/6013/6113

MCTRL-NACT

Actual speed

100 % = 16383

MCTRL-PHI-ACT

Actual phase

MCTRL-MSET2

Torque setpoint in %

100 % = 16383

DF-slave cascade 7003/7013/7113

MCTRL-NACT

Actual speed

100 % = 16383

MCTRL-PHI-ACT

Actual phase

MCTRL-MSET2

Torque setpoint in %

100 % = 16383

not assigned

Cam profiler

1xxx3

MCTRL-NACT

Actual speed

100 % = 16383

not assigned

not assigned

Positioning

2xxx3

MCTRL-NACT

Actual speed

100 % = 16383

not assigned

not assigned

vector control

1xx3/4xx3/5xx3/

10xx3

MCTRL-NACT

Actual speed

100 % = 16383

MCTRL-IACT

MCTRL-NSET2

Speed controller input

100 % = 16383

vector control

6xx3/7xx3/8xx3/

9xx3

MCTRL-NACT

Actual speed

100 % = 16383

MCTRL-PHI-ANA

MCTRL-MSET2

Torque setpoint in %

100 % = 16383

vector control

110x3

not assigned

not assigned

not assigned

For more detailed information about the function block AIF-OUT see the Manual 93XX.