Parameter setting
6-29
L
BA2141 EN 1.0
6.4.2.13
Default value for nviDrvSpeedScale
network input config_lev_percent nciDrvSpeedScale;
This value determines the default setting for
nciDrvSpeedScale
.
The current configuration
variable
nciDrvSpeedScale
is overwritten with the default value
•
after a reset or
•
if the time from
nciRcvHrtBt
passes without an update of the variable
nciDrvSpeedScale
.
Input range
The possible bandwidth for the input variable is between -163.840 % and 163.830 % (resolution
0.005 % ).
The value +163.835 % (7FFF
hex
) is assumed to be wrong.
Standard value
0
SCPT Reference
SCPTdefScale (162)