Installation, 4 control terminals, 10 english – Lenze ETMD Tmd frequency inverter User Manual

Page 11

Advertising
background image

10

ENGLISH

Installation

Terminal Data for control connections

(printed in

bold

= Lenze setting)

28

Digital input Start/Stop

LOW = Stop; HIGH = Run Enable
input resistance = 3.3 kΩ

7

Reference common

8U

Analog input

0 … 10 V

(changeable under C34)

input resistance: >40 kΩ

9

Internal DC supply for setpoint potentiometer +10 V, max. 10 mA

A+

Internal DC supply for external devices

+12 V, max. 50 mA

A1

Digital output configurable with c17

DC 24 V / 50 mA

20

Internal DC supply for digital inputs

+15 V, max. 20 mA

20

E1

Digital input configurable with CE1

Activate fixed setpoint 1 (JOG1)

HIGH = JOG1 active

Both HIGH = JOG3 active

R

i

= 3.3 k

E2

Digital input configurable with CE2

Activate fixed setpoint 2 (JOG2)

HIGH = JOG2 active

E3

Digital input configurable with CE3

Activate DC injection brake (DCB)

HIGH = DCB active

E4

Digital input configurable with CE4

Direction of rotation

LOW = CW rotation
HIGH = CCW rotation

A2

Digital output configurable with c18

DC 24 V / 50 mA

8

I

Analog input (changeable under C34)

input resistance: 150 Ω

7

Reference common

62

Analog output configurable with c08...c11

0...10 V or 2...10 V, max. 20mA

71

RS-485 serial communication input

RXB/TXB (B+)

72

RS-485 serial communication input

RXA/TXA (A-)

LOW = 0 … +3 V, HIGH = +12 … +30 V

Protection against contact

• All terminals have a basic isolation (single insulating distance)
• Protection against contact can only be ensured by additional measures (i.e. double insulation)

3.2.4 Control terminals