Troubleshooting and fault elimination, 5troubleshooting and fault elimination, 21 english – Lenze ETMD Tmd frequency inverter User Manual

Page 22

Advertising
background image

21

ENGLISH

Troubleshooting and fault elimination

(1) The drive can only be restarted if the error message has been reset; see c70

Status

Cause

Remedy

e.g.

Present output frequency

Trouble free operation

O

Stop
(outputs U, V, W inhibited)

LOW signal at terminal 28

Set terminal 28 to HIGH

1

Inhibit
(outputs U, V, W inhibited)

Controller is set up for remote
keypad or serial control (see C01)

Start the controller via the remote
keypad or serial link

Output frequency = 0 Hz
(outputs U, V, W inhibited)

Quick stop activated through digital
input or serial link

Deactivate Quick stop

Flying restart attempt

c42 = 2, 3

DC-injection brake active

DC-injection brake activated
• via digital input
• automatically

Deactivate DC-injection brake
• digital input = LOW
• automatically after holding time c06

has expired

L

Motor calibration is in process c48 = 1 and terminal 28 = HIGH

Only perform the motor calibration
when C14 = 4...7

Current limit reached

Controllable overload

Automatically (see C22)

Undervoltage on DC bus

Mains voltage too low

Check mains voltage

Overvoltage on DC bus during
deceleration (warning)

Excessively short deceleration time
(C13, c03)

Automatically if overvoltage
< 1 s,

U

, if overvoltage > 1 s

No access to code

Can only be changed when the
controller is in

or

Set terminal 28 to LOW or inhibit by
serial link

Remote keypad is active

Attempt to use buttons on front of
controller

Buttons on front of controller are
disabled when remote keypad is active

Error

Cause

Remedy

(1)

A/D converter error

Please contact Lenze

Identification fault

C93 value stored on EPM does not match
controller model

• Use EPM providing valid data
• Load Lenze setting

Data on EPM not valid

Data not valid for controller

Data error

OEM data not valid

L

Automatic start inhibited

c42 = 0, 2

LOW-HIGH signal change at terminal 28

EPM error

EPM missing or defective

Power down and replace EPM

Digital inputs not
uniquely assigned

E1...E4 assigned with the same digital
signals

Each digital signal can only be used
once

Either just “UP” or “DOWN” used

Assign the missing digital signal to a
second terminal

Dynamic braking fault

Dynamic braking resistors are overheating Increase deceleration time

5

Troubleshooting and fault elimination

Advertising