Code

Possible Settings

IMPORTANT

No.

Name

Lenze Selection

Current limit

200

30

{%}

200

Reference:

Tmd

rated output current

• When the limit value is reached, either the

acceleration time increases or the output
frequency decreases

• When c73 = 0, max setting is 167%

Accel boost

0.0

0.0

{%}

20.0 Accel boost is only active during acceleration

Configuration -
analog input

0

0

0...10 V

• Voltage reference applied to 8U

Tmd

does not provide -10 V supply for

C34 = 2

• C34 = 2 disabled in vector torque mode

1

0...5 V

2

-10...+10 V

3

0...20 mA

• Current reference applied to 8I
• C34 = 5 will trigger

fault if signal falls

below 2 mA

4

4...20 mA

5

4...20 mA monitored

WARNING!

When running with -10...+10V reference (C34=2), a loss of reference will result in 5%
motor speed (0.05xC11).

Note

When C34 = 2:
• Rotation is determined by the polarity of the -10...+10 V signal:
+0.1...+10 V = CW and -0.1...-10 V = CCW (all other rotation commands are disabled)
• C11 sets maximum frequency in both directions (C10 is not active)
• CE1...CE4 = 6 or 7 will only start the controller, not select rotation

C

Voltage - DC injection
brake (DCB)

4.0

0.0

{%}

50.0 • See CE1...CE4 and c06

• Confirm motor suitability for use with DC

braking

Fixed setpoint 1
(JOG 1)

20.0

0.0

{Hz}

240 Lenze setting: active at E1 = HIGH

Fixed setpoint 2
(JOG 2)

30.0

0.0

{Hz}

240 Lenze setting: active at E2 = HIGH

Fixed setpoint 3
(JOG 3)

40.0

0.0

{Hz}

240 Lenze setting: active at E1 = HIGH and E2

= HIGH

Frequency setpoint

0.0

{Hz}

240 Display: Setpoint via analog input, function

UP/DOWN, or LECOM

Torque setpoint/range

100

0

{%}

400 • When C14 = 5 and C01 = 1, 5, 7, 9, 11,

sets the torque setpoint

• When C14 = 5 and C01 = 0, 2, 4, 6, 8, 10,

sets the torque range for C34

C

Output frequency

0.0

{Hz}

240 Display

Motor voltage

0

{V}

999 Display

DC bus voltage

0

{V}

999 Display

Motor current

0.0

{A}

400 Display

Controller load

0

{%}

255 Display

C

Motor torque

0

{%}

400 Display: vector mode only (C14 = 4, 5)

Heatsink temp

0

{C}

255 Display