Logic Status Word for PowerFlex 700/700H/700S Drives

The AFE reference is the commanded bus voltage (for example, a value of 6000
represents 600.0V DC). The feedback value is the bus voltage measured in the
AFE.

Logic Bits

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Status

Description

x

Ready

0 = Not Ready
1 = Ready

x

Active

0 = Not Active
1 = Active

x

Motoring

0 = Not Motoring
1 = Motoring

x

Regenerating

0 = Not Regenerating
1 = Regenerating

x

In Precharge

0 = Not In Precharge
1 = In Precharge

x

Droop Active

0 = Not Droop Active for AFE

Paralleling

1 = Droop Active for AFE Paralleling

x

Alarm

0 = No Alarm
1 = Alarm

x

Faulted

0 = Not Faulted
1 = Faulted

x

At Reference

0 = Not At Reference
1 = At Reference

x

Mot CurLim

0 = Not Exceeding Current Limit in

Motoring Mode

1 = Exceeding Current Limit in

Motoring Mode

x

Regen CurLim

0 = Not Exceeding Current Limit in

Regenerative Mode

1 = Exceeding Current Limit in

Regenerative Mode

x

Cmd Delayed

0 = Condition False
1 = Condition True

x

DCVoltRefID0

x

DCVoltRefID1

x

DCVoltRefID2

x

Reserved

Bits

Description

14

13

12

0

0

0

= DC Volt Ref

0

0

1

= Analog In 1

0

1

0

= Analog In 2

0

1

1

= DPI Port 1

1

0

0

= DPI Port 2

1

0

1

= DPI Port 3

1

1

0

= DPI Port 4

1

1

1

= DPI Port 5