The AFE Frame 13 power structure in the IP21 Rittal enclosure contains
common mode capacitors that must be removed

. These capacitors are located

on the Phase V (center) module of the power structure. Use the following
procedure to remove these capacitors from the AFE Frame 13 power structure.

1.

Locate the common mode capacitors on the Phase V module of the Frame
13 power structure.

2.

Remove the common mode capacitors.
a. Disconnect the two black wires.
b. Unscrew and remove the capacitor assembly consisting of two

capacitors on a small metal bracket.

Location of Common Mode
Capacitors on Phase V Module of
Frame 13 AFE Power Structure

Phase V Module of Frame 13
Power Structure

Close-up View of Common
Mode Capacitors on Phase V
Module of Frame 13 AFE
Power Structure

Disconnect Wires and
Unscrew Capacitor Assembly

Close-up View of Common
Mode Capacitor Assembly